Shanghai I Fluid Technology Co., Ltd.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsHigh Pressure Air Flow Meter

Output RS485 High Pressure Air Flow Meter DN15 ISO9001 For Paper Pulp

Good quality Woltman Water Meter for sales
Good quality Woltman Water Meter for sales
Best friends, our truly trusted partner, who help us solve problem, improve efficiency, create value.

—— Mr. Ryes

We've known each other for many years, always strongest support behind us.

—— Mr. Muhammad

I'm Online Chat Now

Output RS485 High Pressure Air Flow Meter DN15 ISO9001 For Paper Pulp

China Output RS485 High Pressure Air Flow Meter DN15 ISO9001 For Paper Pulp supplier
Output RS485 High Pressure Air Flow Meter DN15 ISO9001 For Paper Pulp supplier Output RS485 High Pressure Air Flow Meter DN15 ISO9001 For Paper Pulp supplier

Large Image :  Output RS485 High Pressure Air Flow Meter DN15 ISO9001 For Paper Pulp

Product Details:

Place of Origin: China
Brand Name: Iflow
Certification: ISO9001, CE
Model Number: LGK100

Payment & Shipping Terms:

Minimum Order Quantity: negotiable
Price: negotiable
Packaging Details: carton
Delivery Time: 1-2 weeks
Payment Terms: T/T, L/C, D/P, Western Union
Supply Ability: 5000 pieces per month
Contact Now
Detailed Product Description
Name: Paper Pulp Integrated Orifice Flow Meter Diameter: 15 Mm - 800mm
Accuracy: 1%, 1.5% Housing Material: CS, Stainless, 12cr1MoV
Flow Rate Range: 0.2 ~11 M/s Temperature: 25℃~800℃
Pressure Rating: 0.25 ~60 Mpa Output: 4 ~ 20 MA, 0-1 Khz, RS485
Wet Part Material: Mo2Ti, Hc, Hb, Ta, PT, SS304

Pipe size DN15-DN800 mm high pressure air flow meter, Integrated orifice flowmeter for paper pulp

 

Description

Integrated throttle flowmeter and differential pressure transmitter into one. Differential pressure transmitter and flow display device through the analog signal (4 ~ 20mA) or digital signal (HART protocol) communication, constitute the flow measurement system. The system uses digital integrated throttle flowmeter communication (HART protocol) flow measurement range up to 10: 1 or wider. The integrated throttling flowmeter inherits the medium to adapt to the throttling medium (liquid, gas, steam, general), no moving parts, without the actual calibration (can be measured using the geometric dry method), high temperature and pressure, impact resistance is not easy Deformation and other advantages. At the same time, the system design of antifreeze isolator, instrumentation department need insulation, with heat and condenser, the structure is more reasonable, easy to install, greatly reducing the amount of maintenance. Due to the use of antifreeze isolator greatly reduces the length of the lead tube, low failure rate, good dynamic characteristics.

The configuration of ordinary differential pressure transmitters and ordinary flow display device integrated throttling flowmeter in the flow or pipe conditions change, without the replacement of throttling case, the use of "LG-94-01 version of the throttle Device design computer management software "to recalculate outflow coefficient C, coefficient of expansion ε, full-scale differential pressure value (or full-scale flow value), to modify the flow display device settings and adjust the differential pressure transmitter range. An intelligent, differential pressure transmitter with an integrated throttling flowmeter enables wide-range detection. Flow measurement up to 10: 1 or wider.

 

Product features

  •  Stainless steel pipe flow resistance components, the pressure loss can be low.
  •  can measure most of the media flow.
  •  multi-parameter display: show the flow and differential pressure and pressure.
  •  According to user needs to change the flow range online.
  •  high measurement accuracy, wide measurement range up to 1:10, to meet the trade settlement requirements.
  •  Optional welding structure, measuring high temperature and pressure medium flow measurement.

Technical data

Diameter DN15 - DN2000
Wet part material Mo2Ti,Hc,Hb,Ta,Pt,SUS304,SUS316
Accuracy ±1.0%,±1.5%
Housing material carbon steel, stainless steel, 12cr1MoV, etc
Flow velocity range 0.2 - 11 m/s
Tempearture 25℃~800℃
Pressure rating 0.25Mpa-60Mpa
Cable interface PG10
Protection (transducer) IP65, IP67, IP68
Explosion proof Exmdib IIBT4
Converter type compact / remote
Power supply 85 - 265VAC, 18-36V DC
Power consumption <5w

 

Structure

  •  Throttle: standard orifice, standard nozzle, long diameter nozzle, 1/4 circular orifice plate, double orifice plate, eccentric orifice plate, round orifice plate, conical inlet orifice plate and other pressure device: Flange, clamping ring, pressure pipe and other connecting flange (national standards, various standards and other design sectors of the flange), fasteners. Measuring tube.
  •  Orifice flowmeter installation requirements: The requirements of the straight pipe is generally 5d after the first 10D, so in the purchase of orifice flowmeter must be based on the situation of the flowmeter on-site industrial and mining to choose for the scene of mining flowmeter.
  •  The fluid filled pipes, as they flow through the throttling device in the pipeline, will locally contract at the throttling element of the throttling device so that the flow rate is increased.

Dimensions

 

Output RS485 High Pressure Air Flow Meter DN15 ISO9001 For Paper Pulp

 

 

DN(mm) L(mm) D(mm) H(mm) Weight(kg)
15 150 22 55 10
20 150 25 55 10
25 150 32 55 10
32 150 38 55 10
40 160 46 55 12
50 180 57 55 13
65 200 76 55 14
80 200 89 58 15
100 220 108 60 20
125 250 133 62 22
150 260 159 63 25
200 270 219 66 40
250 300 273 70 60
300 330 329 72 70
350 350 373 75 80
400 360 430 78 90
450 380 480 80 110
500 450 530 82 130
600 420 640 85 150
700 500 740 88 175
800 550 850 90 200