Shanghai I Fluid Technology Co., Ltd.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsUltrasonic Flow Meter

Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment

Good quality Woltman Water Meter for sales
Good quality Woltman Water Meter for sales
Best friends, our truly trusted partner, who help us solve problem, improve efficiency, create value.

—— Mr. Ryes

We've known each other for many years, always strongest support behind us.

—— Mr. Muhammad

I'm Online Chat Now

Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment

China Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment supplier
Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment supplier Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment supplier

Large Image :  Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment

Product Details:

Place of Origin: China
Brand Name: Iflow
Certification: ISO9001, CE
Model Number: TUF2000B

Payment & Shipping Terms:

Minimum Order Quantity: negotiable
Price: negotiable
Packaging Details: carton / wooden case
Delivery Time: 1-2 weeks
Payment Terms: T/T, L/C, Western Union
Supply Ability: 5000 pieces per month
Contact Now
Detailed Product Description
Type: Ultrasonic Flow Meter Transit Time Principle: Transit Time
Transducer: Inline / Clamp On / Insert Accuracy: +/- 1%
Communication: RS485 Modbus Size: DN50-700
Temperature: 90 C / 160 C Converter Mounting: Compact Inline

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

 

Principle of operation

This doppler inline ultrasonic flow meter, employs the frequency shift, that's the Doppler Effect, of an ultrasonic signal when it is reflected by suspended particles or gas bubbles (can be discontinusely) in motion. A metering technology uses the physical phenomenon of a sound wave which changes frequency when it is reflected by the moving discontinuities in a flowing liquid. The ultrasonic sound is transmitted into a pipe with flowing liquids, and the discontinuities reflect the ultrasonic wave with a slightly different frequency that is directly proportional to the rate of flow of the liquid (Figure 1). Current technology requires that the liquid contain at least 100 PPM of 100 micron or larger suspended particles or bubbles.

 

Data sheet

Items Performance & Parameter
Convertor Principle Transit-time ultrasonic flow meter
Accuracy + 1%
Operation 4 keyboards operation
Output signal 1 channel 4-20mA, resistance 0-1K , accuracy 0.1%
1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms)
1 channel relay output
Input signal 3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level)
Temperature transducer Pt100, heat / energy measurement
Communication Galvanic isolation RS485, software upgrade by PC, MODBUS
Signal cable Twisted-pair cable, 50m; RS485, transmission distance 1000m or above.
Connect port Pipe material Steel, stainless, cast iron, copper, cement, PVC, aluminum, etc
Pipe Dia 15 - 6000 mm
Straight pipe Upstream: 10xDia, or downstream: 5xDia, and 30xDia from pump
Metering Liquid type

Single sonic wave transmittable liquid, such as municipal water, cooling

water,

seawater water, waste water, pure water, Sewage with particle content, such

as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

heating, ventilation ,air conditioner, power plants,

  Temperature -30-160℃
  Turbidity Up to 10000 ppm and less bubble
  Flow velocity 0-7 m/s
Work environment Temperature Convertor: -20-60 ℃, Transducer: -30-160℃
Humidity Convertor: 85%RH, Transducer: submersible up to depth 2m
Power supply DC8-36V or AC10-30V / 1.5W
Dimension Convertor: 95*95*35mm

 

Features:

  •  Non-Intrusive, transducer for Most Pipes from DN32 to DN6000mm
  •  Inline pipe type , insertion type or clamp on probe transducer for options
  •  Wide Measuring Range of 0.05 to 9 mps
  •  ±2% of Calibrated Span Accuracy
  •  Configuration and Total Stored in SD
  •  Protection IP65 for housing, IP68 for transducer

Metering Diagram

Flow measurement Heat measurement

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water TreatmentDoppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

Reference chart

Type Model Pipe dia (mm) Temperature Dimension (mm)
Clamp on TS-2 DN15-100 -30-90℃ 45x25x32
TM-1 DN50-700 -30-90℃ 64x39x44
TL-1 DN300-6000 -30-90℃ 97x54x53
Clamp on (high temperature) TS-2-HT DN15-100 -30-90℃ 45x25x32
TM-1-HT DN50-700 -30-90℃ 64x39x44
TL-1-HT DN300-6000 -30-90℃ 97x54x53
Insertion type TC-1 DN80-6000 -30-90℃ 190x80x55
TC-2(lengthen) DN80-6000 -30-90℃ 335x80x55
Pipe type G3 (π type) DN15-25 -30-160℃  
G2 DN32/DN40 -30-160℃  
G3 DN50-6000 -30-160℃  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional temperature transducer

Specification Model Dia Temp. Water cut Accuracy
Clamp-on temp. transducer Pt100 CT-1 >DN50 -40-160℃ No 100+ 0.8℃
Insertion temp. Transducer Pt100 TCT-1 Yes
Insertion temp. Pt100 with pressure PCT-1 No
Insertion temp.Pt100 for small pipe D SCT-1 <DN50 Yes

 

 

 

 

 

 

Industries

  •  Chemicals
  •  Petrochemicals
  •  Oil & Gas
  •  Heating, Ventilation & Air Conditioning (HVAC)
  •  Power Plants
  •  Water treatment

Applications

  •  Metering of cooling water
  •  Demineralisedwater
  •  Control of batching and blending operations
  •  Mass flow measurement
  •  Allocation measurement
  •  District heating
  •  Irrigation
  •  Energy measurement

Model Selection

I Model              
  YF Electromagnetic flowmeter
  TF Turbine
  VF Votex
  LX Vane wheel
  T Ultrasonic
    E/F display mode E: compact/local display, F: remote display
      Pipe Dia Type (mm)
      xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

400, 500, 600, 800, 1000

      Code Accuracy
      1 + 0.5% FS
      2 + 1.0% FS
      3 + 0.2% FS
        Code Type
        N Converter: 12 / 24 VDC, pulse output
        A Transmitter: 24VDC, 4-20mA outpt
        B Intelligent, Lion battery, no local display
        G Smart, local display, 4-20mA output
        C1 Smart, local display, RS485
        C2 Smart, local display, HART
          Code Type
          S Carbon steel housing
          L Stainless steel housing
          G High pressure housing
          HL 316L electrode
          HTi Titanium electrode
          HTa Tantlum electrode
          HC Hastelloy-C electrode
          L1 Liquid media
          L2 Gas media
          P Pressure compensation
          T Temperature compensation
          PT Pressure&Temp. Compensation
          F PTFE liner
          X Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F,

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

RS485, 316L electrode, liquid media meter, PTFE liner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Competitive Advantage:

  •  Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  •  CE approval
  •  Strict process control
  •  Advanced calibration equipment
  •  Engineer team

Contact Details
Shanghai I Fluid Technology Co., Ltd.

Contact Person: Yuan

Send your inquiry directly to us (0 / 3000)